Heavy-Load Server Room Raised Floor System

Ipawit so Pantepet
Heavy-Load Server Room Raised Floor System
Saray detalye
Say FineCo Heavy-Load Server Room Raised Floor System et ginawa parad high-density data centers, enterprise server rooms, tan mission-critical technical spaces. Sayan sistema et adesinyo pian suportaan iray konsentradon karga manlapud blade servers, mainframes, tan heavy power distribution units (PDUs), tan manguusar na makapal iran materyales ya akapeket ed sakey a welded steel shell.
Kategorya
High Load Raised Access Flooring Systems
Share to
Deskripsyon

Heavy-Load Server Room Raised Floor System|FineCo Global

 

Say FineCo Heavy-Load Server Room Raised Floor System et ginawa parad high-density data centers, enterprise server rooms, tan mission-critical technical spaces. Sayan sistema et adesinyo pian suportaan iray konsentradon karga manlapud blade servers, mainframes, tan heavy power distribution units (PDUs), tan manguusar na makapal iran materyales ya akapeket ed sakey a welded steel shell.

 

Saray Manunan Tampok

 

Atagey a Resisti ed Karga:Saray welded steel ya istruktura tan saray makapal ya inner cores et mangaamper ed permanentin deformation ed silong na concentrated loads ya onlampas ed 2,500 lbf (11.1 kN).
Kontroladon ESD Dissipation:Saray surface laminates et walaan na tuloytuloy ya resistensya na kuryente ya 1 × 106 anggad 1 × 109 ohms pian naprotektaan so sensitibon IT hardware.
Rigid Substructure Grid:Saray ambelat ya pedestal tan bolt-in stringers so mangikandado ed saray panel ed sakey a matrix, ya mamaandi ed lateral shifting tan panel dislodgement.
Vertical Levelling Tolerance:Saray pedestal heads et mangiiter na ±25 mm ya vertical adjustment range pian nabawi so ag-inkaparpareho na semento iran subfloor.

 

Istruktura na Sistema

 

Say kompleton pangipuesto et tugyopen na apatiran manunan kabiangan na karga-transfer:
Access Floor Panels:600 × 600 mm ya modules ya walay tapew ya steel sheet resistance- ya inwelding ed sakey ya aporma ya bottom pan, ya napno na magaan ya semento odino high-density ya calcium sulfate.
Pedestal Assemblies:Electro-galvanized steel threaded rods, 100 × 100 × 4 mm base plates, tan die-cast heads ya walay vibration-damping gaskets.
Bolt-In Stringers:I-roll-naporma iray asero ya kanal ya aka-lock ed saray ulo na pedestal pian makaporma na malet ya grid matrix parad mas malet ya lateral stability.
Perimeter Trims & Gaskets:Saray mekanikal ya fasteners tan saray closed-cell foam seals ya mangaamper ed itatagey na dagem tan mamatunda ed acoustic resonance.

 

Teknikal iran Detalyado

 

Espesipikasyon na Bengatla

Standard Steel Panel + Concrete Core

High-Density Calcium Sulfate Core

Sukat na Panel

600 × 600 × 35 mm

600 × 600 × 36 mm

Konsentradon Karga

4.45 kN - 11.12 kN (1,000 - 2,500 lbf)

Anggad 13.34 kN (3,000 lbf)

Uniform Load (UDL)

12,000 N/m2 anggad 18,000 N/m2

16,000 N/m2 anggad 20,000 N/m2

Safety Factor

Mas baleg odino mipara ed 3.0× Ultimate Load

Mas baleg odino mipara ed 3.0× Ultimate Load

Say Sentro ya Ipaliis

Mas abeba o mipara ed 2.0 mm ed sankatageyan ya karga

Mas abeba o mipara ed 1.5 mm ed sankatageyan ya karga

Surface Resistance

106 - 109 Ω (HPL / Conductive PVC)

106 - 109 Ω (HPL / Conductive PVC)

Fire Rating

Flame Spread 0, Smoke Developed 0 (ASTM E84)

Class A / Non-combustible (EN 13501-1)

 

Seismic Performance

 

Braced Frame Compatibility:Susuportaan toy ambelat ya seismic stringer attachments tan diagonal cross-bracing parad Zone 4 odino Seismic Design Category D-F compliance.
Dynamic Load Testing:Sinubok ed silong na cyclic lateral loads pian naprebentaan so structural racking tan napansiansia so alignment legan na seismic events.
Positibon Pankandado:Say Bolt-in stringers et mangiseseguro ed saray panel sumpad iyalis na tagey lapud pressure differentials odino yegyeg.

 

Saray kaslakan ya aplikasyon

 

  • Hyperscale tan Enterprise Data Centers
  • Telecommunication Switching Centers
  • Network Operations Centers (NOC)
  • UPS tan Battery Backup Rooms
  • Importante iran Kuarto na Kontrol ed Industriya

Pangipuesto tan Pangisadya

 

Asumpal ya Katagey na Datal (FFH):Say estandarten manlapud 300 mm anggad 1,200 mm parad underfloor HVAC plenums tan cable trays.
Perforated Panels:Saray module na panagbunog na dagem ya walay 25% anggad 55% ya lukas ya lugar tan saray adjustable sliding dampers.
Saray Cutouts tan Grommets:Say pabrika o lugar-putoten iray lukas na kable ya walay brush seal pian ag-onkulang so dagem.
Panagparaan ed silong na datal:Kaukolan so malinis ya semento ya subfloor ya in-treat na anti-dust acrylic sealer antis ya i-install so pedestal.

 

Saray Estandarte tan Kalidad

 

CISCA:Saray paraan na panagsubok na konsentrasyon, panag-roll, tan sankaabigan ya karga.
EN 12825:Saray totontonen ed performance tan klasipikasyon na saray atagey ya access floors.
ASTM E84 / UL 723:Saray katangian na panagpoolan ed tapew na saray materyales ed panagpaalagey.
ISO 9001:2015:Saray sistema na panangasikaso ed kalidad ya mangokontrol ed panag-trace na raw materials tan saray automated spot-welding tolerances.

 

Panaggawa tan Suporta ed Proyekto

 

Kapasidad na Produksyon:Saray automated stamping lines tan robotic resistance welders et makapangiter na binulan ya output ya masulok ya 100,000 m2.
Nasubaybayan so Materyal:Saray steel sheets ya nanlapud saray gilingan ya walaan na saray report nipaakar ed kemikal a komposisyon; core density ya apaneknekan panamegley na batch testing.
Saray Drowing ed Tindaan:Say grupo na inhenyero so mangiiter na saray plano na layout na CAD, eskedyul na katagey na pedestal, tan saray panag-optimize na panagputot base ed saray drowing na arkitektura.
Logistics Packaging:Saray panel ya akatapew ed saray paleta ya anggapoy fumigation-, shrink- ya abalkot na waterproof membranes, tan pinabiskeg parad kargamento ed dayat.

 

Mabetbet ya Itepet

 

T: Panon kon naamtaan so suston load rating parad datal na server room mi?

A: Ibase so pilien mo ed sankabelatan ya belat na sakey a kagawaan (singa say napnon kargaan ya server rack odino battery cabinet) tan say dinamikon pangipaalagey. Parad saray estandarten enterprise racks ya kulang na 1,000 kg, say CISCA Grade Heavy Load (11.1 kN / 2,500 lbf) ya sistema ya walay calcium sulfate odino reinforced concrete core so nirekomenda pian naprebentaan so panel deflection ed silong na rolling caster wheels.

T: Antoy pandumaan na semento tan saray panel ya walay calcium sulfate?

A: Saray asero ya panel ya napno na semento et walaan na atagey ya inkapekder na istruktura, resistensya ed epekto, tan inkaepektibo ed gastos. Saray calcium sulfate panel et mangiiter na superyor ya acoustic dampening, mas makapal ya pakalikna, mas atagey ya ultimate load capacities, tan inherent non-combustible core properties parad saray pasilidad ya atagey-density.

T: Panon ya naasikaso na sistema so grounding tan electrostatic discharge?

A: Saray panel et mankokonektaan na kuryente ed saray ulo na pedestal panamegley na saray conductive gaskets odino direktan metal ya kontak. Saray pedestal et igaton ed sakey a copper grounding grid network ya uusaren iray mekanikal a clamp odino copper tape, ya pansiasiansiaen so path-to-ground resistance ed loob na estandarten safety thresholds.

T: Antoy estandarten lead time parad saray bulk project orders?

A: Say panaon na produksyon et manlapud 15 anggad 25 ya agew, depende ed karakel na order tan saray custom cutouts. Saray partial shipments et nayarin i-schedule parad angkakabaleg iran data center rollouts pian mipara ed saray on-site construction milestones.

T: Sarag kasi ya iyalis iray ambelat ya server rack ed saray rolling casters ed sayan datal?

A: On. Say sistema et makaanos ed saray rolling loads ya akasulat ed silong na saray totontonen na CISCA (nasubok ed 1,000-lb ya karga ed loob na 10,000 a siklo). Saray protektibon hardboard odino track sheets so nirekomenda legan na unonan ambelat a panag-rigging pian ag-onkupas so tapew na HPL finishes.

Saray Mainit ya Tag: heavy-load server room raised floor system, China heavy-load server room raised floor system manufacturers, suppliers, factory

Ipawit so Pantepet