Say FINECO data center raised access floor systems et ginawa parad server room environments ya walaan na nanduruman load-bearing requirements. Saya so ondalan ed malet ya panangusisa unong ed CE tan CISCA standardized protocols pian naseguro so sigpot a panumbok ed saray kalidad na kriterya na FINECO.
Kategorya
Raised Access Floor Systems
Share to
Deskripsyon

Say FINECO data center raised access floor systems et sakey a balibalin opsyon parad saray modernon pasilidad. Lapud walaan na matalonggaring a inkadukey, epektibon panangasikaso ed kable, tan superyor a kapasidad na panag-awit, saya so matukoy ed nanduruman kaliberliber. Say modular ya konstruksion et mangiiter na maples ya pangi-install tan inka-flexible ed panag-reconfigure. Lapud walay anti-static tan fire-resistant ya features, saya so manggagawa na mas maligen tan mas organisadon pasen. Perpekto parad saray data center, opisina, tan industrial spaces-paaligwasen so inkaepektibo tan karakpan na solusyon.

 

Detalyado na produkto

 

Modelo

Konsentradon Karga

Impact Load

Ultimate Load

Unipormin Karga

Rolling Load (N)

LB

N

N

N

N/㎡

10 beses

10000 beses

FS800

800

3560

536

10680

16100

3560

2670

FS1000

1000

4450

670

13350

23000

4450

3560

FS1250

1250

5560

780

16680

33000

5560

4450

FS1500

1500

6660

1005

19980

34500

6675

5340

FS2000

2000

8900

1340

26700

46000

8900

7120

* Unong ed saray nirekomenda na CE& CISCA ya paraan na panag-test parad Access Floors

600*600mm/24'*24' (610*610mm) ya wala

 

Tampok tan aplikasyon na produkto

 

Parad saray kakaukolanen ed imprastraktura natan, say FINECO data center raised access floor systems so mangiiter na malet tan napanmatalkan iran solusyon. Ginawa manlapud atagey-biskeg, anti-asero tan pinaltog na materyales ya ag-onkapuy, sarayan panel et walaan na makapadinayew a kapasidad a mangawit na karga tan andukey a panaon. Say modular ya desinyo et mamapasimpli ed maples ya pangi-install, simplin pangi-reconfigure, tan anggapoy problema ed saray underfloor utilities, ya mamaaligwas ed operational efficiency. Lapud walay integrated cable management channels ya mamaaligwas ed airflow tan mangorganisa na power/data cabling, nabawasan so clutter. Maong parad mairap iran kaliberliber a singa saray data center, pasilidad na industriya, command control room, tan laboratoryo, saray steel raised floors so manggagarantiya na kaligenan, inka-flexible, tan panumbok ed saray internasyonal ya estandarte, ya makatunongan ed saray dinamikon pankaukolan ed pasen ya daiset so panmintina.

 

Detalye na produkto

image001

Say The FINECO data center raised access floor systems et walaan na eksakton -engineered ya aspekto parad sankaabigan ya performance. Saray ESD edge trims et mangiseguro na andiay depekto ya konduktibidad tan static dissipation ed interon sistema na datal. Kada panel et ondalan ed estrikton epoxy powder-coated anti-rust treatment, pian naseguro ya ag-onkupas ed ambetel odino maruksan kaliberliber. Say nanduruman anti-static laminate options (HPL, PVC, ceramic) et mangiiter na na-customize ya aesthetics legan ya mansiasiansia so 10^4–10^9Ω ya resistensya ed tapew. Saray pinabiskeg ya bolted stringers et mamaaligwas ed inkapekder na istruktura, ya onsuporta ed saray point loads ya anggad 890kg. Saray Fire-rated cores et makaabot ed ASTM E84 Class 1 ya estandarte. Saray opsyonal ya gasket-sealed ya gilig et manporma na air-tight ya kompartimento parad malinis a kuarto odino saray aplikasyon ya walay presyon, ya mangipapanengneng na inka-versatility ed nanduruman teknikal iran detalye.

Kwalipikasyon na Produkto

product-800-451

Say FINECO data center raised access floor systems et adesinyo tan ginawa pian naabot so sankatageyan ya kalidad tan inkadukey. Nanlapud superyor iran materyales tan eksakton panaggawa. Saray manunan elemento et ginawa manlapud atagey a klase na ST14 tan SPCC ya asero, ya kabkabat ed nikadkaduman biskeg, ag-inkayadyari, tan inka-formable, ya mangiseguro na integridad na istruktura ed mairap iran kaliberliber.

 

Say anlemew ya foam concrete et inyarum pian napaaligwas so performance. Saya so mamapaabeba ed kabuoan a belat tan mangiiter na ekselentin thermal insulation, sound absorption, tan eco-friendly ya kalidad. Say proseso na panaggawa et manguusar na mabiskeg iran high-tonnage presses ya mangiiter na steady pressure tan eksakton panagporma, ya mamaandi na depekto ed materyales tan mangigarantiya na inkasusto na sukat.

product-800-466
image007

Say pangusar na nanlaok ya abangonan iran materyales tan atagey a kalidad na industrial-grade ya kagawaan ed proseso na panaggawa tayo et mangitonton ed produksyon na saray produkto ya naynay ya onlampas ed saray estandarte na industriya parad inkadukey, inkamatoor, tan inkaekselente na operasyon. Komitido kamin makasumpal tan makalampas ed saray sanka-istriktoan ya iilaloan na saray kustomer mi, ya iter ed sikara iray produkto ya walaan na nikadkaduman kalidad tan performance, tan seguroen so inkakontento tan kompiyansa ra ed saray produkto tan serbisyo mi.

Panangipawit tan Pakete

 

product-457-575image011

 

FAQ

 

Q: 1. Sarag kasi ya i-adjust so data center raised access floor systems kayari na pangi-install?

A: On. Saray adjustable pedestals ed data center raised access floor systems et mangiiter na pankanawnawan manguman ed katagey pian onkana ed balon kagawaan odino manguman ed saray rota na kable. Say pangiyarum o pangekal na saray panel et sakey ya opsyon, kanian sarayan sistema et mainomay ya onadapta ed manguuman iran sirkumstansya.

T: 2. Panon ya napaaligwas na data center raised access floor systems so dagem ed saray data center?

A: Diad silong na datal, walay plenum ya nagawa pian mangibunog na ambetel ya dagem panamegley na saray abut a baldosa odino bentilasyon ya anggad saray server rack. No onlelereg so ambetel ya dagem ed tagey, nagawa so sakey a closed-loop cooling system, ya mamaaligwas ed enerhiya tan mangamper ed saray hotspot.

Q: 3. Panon kon napansiansia so data center ya atagey so access floor systems to?

A: Say panggawa na regular ya inspeksion parad saray malukak a panel odino aderal iran suporta et sakey a pankaukolan. Kaukolan so pan-vacuum o pan-sweep ed dalem na datal pian naekal iray basura. Paliisan so ambelat iran karga ya onlampas ed nibaga ya kapasidad. Salatan iray aderal ya panel ed dugan panaon tan seguroen ya akauksoy so kable pian ag makaamper.

T: 4. Iner so pakaromogan ko na kaaruman iran rekursos o suporta?

A: Mitongtong ed data center raised access floor systems supplier parad saray teknikal a giya, video ed panag-instalar, odino on-konsultasyon ed lugar. Tandaan ya saray asosasyon na industriya a singa say BICSI (Building Industry Consulting Services International) so mangiiter na sankaabigan iran kagagawa tan materyales ed panagpasal.

T: 5.Antoy pandumaan na data center ya atagey so access floor systems tan say regular ya floor?

A: Saray data center raised access floor systems et nibiig ed atagey ya istruktura ra, ya mangiiter na mas dakel ya espasyo parad wiring tan equipment management. Wala met so anti-static, fire-resistant, tan load-bearing ya kalidad da. Saray regular ya datal ya akapuesto ed dalin et anggapoy sarayan features.

 

Saray Mainit ya Tag: data center raised access floor systems, China data center raised access floor systems manufacturers, suppliers, factory

Ipawit so Pantepet