Anti Static Raised Access Computer Floor

Ipawit so Pantepet
Anti Static Raised Access Computer Floor
Saray detalye
Say FINECO anti static raised access computer floor et espisipikon adesinyo parad saray kaliberliber na server room ya mankaukolan na nanduruman load-bearing capabilities. Saya so nipaarap ed malet ya ebalwasyon ya ontumbok ed saray standardized protocol na CE tan CISCA pian naseguro so sigpot a panumbok ed saray kalidad na kriterya na FINECO.
Kategorya
Atagey ya Access Computer Floor
Share to
Deskripsyon

Parad saray modernon pasilidad, say anti static raised access computer floor na FINECO et sakey a maabig ya opsyon, ya mangiyoopresi na nikadkaduman inkadukey, epektibon panangasikaso na kable, tan matalonggaring a kapasidad ya mangawit na karga. Say modular ya konstruksion et mamapasimpli ed maples ya pangipuesto tan inka-flexible parad pananguman. Lapud walay anti-static tan fire-resistant ya features to, naseguro toy mas maligen tan mas organisadon kaliberliber. Perpekto parad saray data center, opisina, tan industrial spaces-mamaaligwas ed inkaepektibo tan karakpan na solusyon ya adesinyo pian mansiansia.

 

Detalyado na produkto

 

Modelo

Konsentradon Karga

Impact Load

Ultimate Load

Unipormin Karga

Rolling Load (N)

LB

N

N

N

N/㎡

10 beses

10000 beses

FS800

800

3560

536

10680

16100

3560

2670

FS1000

1000

4450

670

13350

23000

4450

3560

FS1250

1250

5560

780

16680

33000

5560

4450

FS1500

1500

6660

1005

19980

34500

6675

5340

FS2000

2000

8900

1340

26700

46000

8900

7120

* Unong ed saray nirekomenda na CE& CISCA ya paraan na panag-test parad Access Floors

600*600mm/24'*24' (610*610mm) ya wala

 

Tampok tan aplikasyon na produkto

 

Say FINECO anti static raised access computer floor et mangiiter na malet tan napanmatalkan iran solusyon parad saray kakaukolanen ed imprastraktura natan. Ginawa manlapud atagey-biskeg, anti-asero tan pinaltog na materyales ya ag-onkapuy, sarayan panel et walaan na nikadkaduman kapasidad a mangawit na karga tan andukey a panaon. Say modular ya desinyo et mamapasimpli ed maples ya pangi-install, mainomay ya i-reconfigure, tan anggapoy problema ya makaloob ed saray underfloor utilities, ya mamaaligwas ed operational efficiency. Lapud saray integrated cable management channels ya mamaaligwas ed airflow tan mangorganisa na power/data cabling, nabawasan so clutter. Maong parad mairap iran kaliberliber a singa saray data center, pasilidad na industriya, command control room, tan laboratoryo, saray steel raised floors so mamaseguro na kaligenan, inka-flexible, tan panumbok ed saray internasyonal ya estandarte, ya makatulong ed saray dinamikon pankaukolan ed pasen ya daiset so panmintina.

 

Detalye na produkto

image001

Say FINECO anti static raised access computer floor et walaan na precision-engineered ya aspekto parad sankaabigan ya performance. Saray ESD edge trims et mangiseguro na andiay depekto ya konduktibidad tan static dissipation ed interon sistema na datal. Kada panel et ondalan ed estrikton epoxy powder-coated anti-rust treatment, pian naseguro ya ag-onkupas ed ambetel odino maruksan kaliberliber. Say nanduruman anti-static laminate choices (HPL, PVC, ceramic) et mangiiter na customizable ya aesthetics legan ya mansiasiansia so 10^4–10^9Ω ya resistensya ed tapew. Saray pinabiskeg ya bolted stringers et mamaaligwas ed inkapekder na istruktura, ya onsuporta ed saray point loads ya anggad 890kg. Saray Fire-rated cores et makaabot ed ASTM E84 Class 1 ya estandarte. Saray opsyonal ya gasket-sealed ya gilig et manporma na air-tight ya kompartimento parad malinis a kuarto odino saray aplikasyon ya walay presyon, ya mangipapanengneng na inka-versatility ed nanduruman teknikal iran detalye.

Kwalipikasyon na Produkto

product-800-451

Say FINECO anti static raised access computer floor et adesinyo tan ginawa pian nasumpal so sankatageyan ya estandarte na kalidad tan inkadukey, ya onggapo ed atagey-kalidad iran materyales tan eksakton panaggawa. Saray manunan kabiangan et ginawa manlapud atagey a klase na ST14 tan SPCC ya asero, ya bantog ed makapadinayew ya biskeg, ag-inkayadyari, tan inka-porma, ya mangiseguro na integridad na istruktura ed mairap iran kaliberliber.

 

Say anlemew ya foam concrete et inyarum pian napaaligwas so performance, ya mamapaabeba ed belat tan mangiyoopresi na maabig ya thermal insulation, sound absorption, tan ag makaderal ed kaliberliber. Say panaggawa et manguusar na mabiskeg, atagey a -tonnahe ya panag-imprinta ya mangiiter na pareparehon presyon tan eksakton panagporma, ya mamaandi ed saray depekto na materyales tan manseguro na inkasusto na sukat.

product-800-466
image007

Say panlalaok na saray abangonan a materyales tan industrial-grade ya kagawaan so mangitonton ed produksyon na saray produkto ya tuloytuloy ya onlampas ed estandarte na industriya parad inkadukey, inkamapanmatalkan, tan inkaekselente na operasyon, ya manusumpal ed sanka-istrikton iilaloan na saray kustomer.

Panangipawit tan Pakete

 

product-457-575image011

 

FAQ

 

T: 1. Antoy anti static raised access computer floor system?

A: Say anti static ya atagey ya access computer floor, ya walaan na saray interlocking panels tan support pedestals, et manporma na atagey ya plataporma ed tagey na wala lan datal. Saya so mamapawala na saray kable, utilities, tan HVAC systems ed leksab, ya mangiiter na mainomay ya access parad maintenance tan flexibility ya i-adjust so layout.

Q: 2. Kasin say anti static raised access computer floor et makaresisti ed apoy?

A: No nipaakar ed anti static raised access computer floor, dakel ed saray kabiangan to so makaabot ed saray estandarte na kaligenan ed pool (alimbawa, Class A rating). Say pangusar na materyales a singa say asero odino fire-retardant laminates et ontulong pian nabawasan iray peligro. Balet tandaan ya nengnengen iray lokal a kodigo tan seguroen ya wala ray suston sistema na panag-ekal na apoy.

T: 3. Anto ran isyu so nayarin naeksperiensya ko ed anti static raised access computer floor?

A: Saray isyu ya nayarin nagawa et say paka-deformate na panel lapud alablabas ya belat, say inka-congestion na kable ya mangaamper ed iyaagus na dagem, odino saray malukak ya baldosa ya pansengegan na peligro. Say regular ya panmintina tan panumbok ed saray limitasyon na karga et makatulong pian nabawasan irayan peligro.

T: 4. Nayarin i-install so anti static raised access computer floor ed tapew na wala lan datal?

A: On, say anti static raised access computer floor et walay flexibility ya i-install ya direkta ed tapew na wala lan semento, baldosa, odino carpeted surfaces, basta say subfloor et patag tan malet so istruktura to. Makatipid iya na panaon tan gastos no ikompara ed pangekal ed orihinal ya datal.

T: 5. Panon kabayag so pangipaalagey na anti static raised access computer floor?

A: Say panaon na pangipaalagey et naimpluensyaan na kabaleg tan inkakomplikado na lugar. Saray melag a lugar et nayarin nasumpal ed loob labat na pigaran agew, saray angkakabaleg a data center et nayarin mangala na pigaran simba. Say panagplano tan pitongtong ed saray grupo na HVAC tan electrical et importante.

 

Saray Mainit ya Tag: anti static raised access computer floor, China anti static raised access computer floor manufacturers, suppliers, factory

Ipawit so Pantepet