Say micro cementitious raised access floor na FINECO ya matukoy parad kaplesan iran pasilidad et nikadkaduma lapud nikadkaduman inkadukey to, ag-onsaew a panangasikaso na kable, tan matalonggaring a kapasidad ton mangawit na karga. Say modular ya inkagawa na desinyo to et mamapasimpli ed maples ya pangi-install tan inka-flexible ed pangi-reconfigure. Lapud walaan na anti-static tan fire-resistant ya kalidad, saya so mamaseguro na mas maligen tan mas istrukturadon kaliberliber. Say marakep ya paraan parad saray data center, opisina, tan industriyal iran pasen-mamaaligwas ed inkaepektibo tan karakpan ya uusaren so solusyon ya adesinyo parad andukey a bilay.
Detalyado na produkto
|
Modelo |
Konsentradon Karga |
Impact Load |
Ultimate Load |
Unipormin Karga |
Rolling Load (N) |
||
|
LB |
N |
N |
N |
N/㎡ |
10 beses |
10000 beses |
|
|
FS800 |
800 |
3560 |
536 |
10680 |
16100 |
3560 |
2670 |
|
FS1000 |
1000 |
4450 |
670 |
13350 |
23000 |
4450 |
3560 |
|
FS1250 |
1250 |
5560 |
780 |
16680 |
33000 |
5560 |
4450 |
|
FS1500 |
1500 |
6660 |
1005 |
19980 |
34500 |
6675 |
5340 |
|
FS2000 |
2000 |
8900 |
1340 |
26700 |
46000 |
8900 |
7120 |
* Unong ed saray nirekomenda na CE& CISCA ya paraan na panag-test parad Access Floors
600*600mm/24'*24' (610*610mm) ya wala
Tampok tan aplikasyon na produkto
Say micro cementitious raised access floor na FINECO et ginawa pian mangiter na mabiskeg tan napanmatalkan iran solusyon parad saray pankaukolan na modernon imprastraktura. Ginawa ya inusar so atagey a biskeg, anti- a materyales ya ag-onkupas tan pinaltog na saray substansia ya ag-onkapuy, sarayan datal et mangiiter na matalonggaring a kapasidad a mangawit na karga tan manbayag. Say modular ya inkagawa na desinyo et mangiiter na maples ya pangi-install, mainomay ya i-reconfigure, tan anggapoy problema ed saray underfloor utilities, kanian napaaligwas so operasyon. Say integrated cable management channels et ontulong pian napaaligwas so dagem tan naorganisa so power/data cabling, ya nabawasan so clutter. Perpekto parad saray mairap ya senaryo a singa say data center, pasilidad na industriya, command control room, tan laboratoryo, saray micro cementitious ya atagey a datal so mangiseguro na kaligenan, inkaadapta, tan panumbok ed saray internasyonal ya estandarte, ya onsusuportad saray dinamikon pankaukolan ed espasyo ya daiset so sagpot ed panagmintina.
Detalye na produkto

Say FINECO micro cementitious raised access floor et nikadkaduma lapud saray aspekto ton eksakton inhinyero parad sankaabigan ya performance. Saray ESD edge trims et mangiseguro na perpekton konduktibidad tan static dissipation ed interon sistema na datal. Kada datal et ondalan ed istrikton epoxy powder-coated ya anti-rust treatment, ya mangigarantiya na resistensya ed corrosion ed ambetel odino malet iran kaliberliber. Say nanduruman anti-static laminate options (HPL, PVC, ceramic) et mangiiter na na-customize ya itsura legan ya mansiasiansia so 10^4–10^9Ω ya resistensya ed tapew. Saray pinabiskeg ya bolted stringers et mamabiskeg ed inkapekder na istruktura, ya makatulong ed saray point loads ya anggad 890kg. Saray Fire-rated cores et mitunosan ed ASTM E84 Class 1 ya estandarte. Saray opsyonal ya gasket-sealed ya gilig et manporma na air-tight ya kompartimento parad malinis a kuarto odino pressured iran situasyon, ya mangipapanengneng na inka-versatile ed teknikal iran detalye.
Kwalipikasyon na Produkto

Say FINECO micro cementitious raised access floor et ginawa unong ed sankatageyan a kalidad tan inkadukey na saray kriterya, a nanlapud saray premium a materyales tan eksakton panaggawa. Saray manunan kabiangan et manguusar na atagey ya -grade ST14 tan SPCC ya asero, ya kabkabat lapud nikadkaduman biskeg da, resistensya ra ed corrosion, tan inkaporma, ya mangiseguro na integridad na istruktura ed mairap iran kaliberliber.
Say pangiyarum na magaan ya foam concrete et mamaaligwas ed performance, ya mamapaabeba ed belat legan ya mangiiter na sankaabigan ya thermal insulation, sound absorption, tan eco-friendly features. Say produksyon et manguusar na heavy-duty, atagey-tonnage ya panag-imprinta pian nawalaan na pareparehon presyon tan eksakton panagporma, ya naekal iray isyu ed materyal tan naseguro so inkasusto na sukat.


Say pankasakey na saray komplikadon materyales tan atagey a klase na kagawaan ed industriya so mangiter na saray opresi ya tuloytuloy ya onlampas ed saray estandarte na industriya parad inkadukey, inkamapanmatalkan, tan inkasuperyor na operasyon, ya mitunosan ed sankaeksakton iilaloan na saray kustomer.
Panangipawit tan Pakete


FAQ
T: 1. Anto ray kaslakan ya uusaren na micro cementitious raised access floor?
A: Saray micro cementitious raised access floors et kaslakan ya uusaren ed saray data center, server room, opisina, laboratoryo, control room, tan arum niran kaliberliber ya mankaukolan na cable management, airflow control, odino say posibilidad ya umanen iray layout na imprastraktura. Mangiiter met ira na electrical grounding tan static protection ed saray sensitibon lugar.
Q: 2. Panon ya ipuesto so micro cementitious raised access floor?
A: Legan na pangi-install, say subfloor et i-level, saray support pedestal et i-posisyon, saray beam o stringer et i-attach, tan saray floor panel et niiyan. Say katagey et nayarin i-adjust diad tulong na saray pedestal pian nasumpal iray espisipikon kakaukolanen. Saray tahi ed baetan na saray panel et selyado pian naseguro ya ag-onloob so dagem, tan say gilig et inyarum pian ag-onloob, pian nasumpal so pangipuesto.
Q: 3. Panon kon napansiansia so micro cementitious ya atagey ya access floor?
A: Say regular ya inspeksion pian nanengneng iray malukak a panel odino aderal iran suporta et baleg so kabaliksan to. Say pan-vacuum o pan-sweep ed dalem na datal et epektibon paraan pian naekal iray basura. Importante ya paliisan so ambelat iran karga ya onlampas ed nibaga ya kapasidad. Saray aderal ya panel et nepeg ya salatan a tampol, tan nepeg ya seguroen ya akauksoy so kable pian anggapoy makaamper.
T: 4. Antoy kaslakan ya kapasidad na karga na sakey a micro cementitious ya atagey ya access floor?
A: Saray kapasidad na karga et aliwan parepareho. Bangta saray estandarten sistema et makasuporta na 662 anggad 2000 pounds kada square foot (psf), saray lugar ya atagey so densidad da a singa saray data center et nayarin mankaukolan na 2,000+ psf. Parad suston impormasyon nipaakar ed espisipikon pangipaalagey, lanang ya nengnengen iray detalye na manggagawa.
T: 5. Panon ya napaaligwas na micro cementitious raised access floor so dagem ed saray data center?
A: Diad panggawa na plenum ed silong na datal, say ambetel ya dagem et nitaytayak ed saray abut a baldosa odino bentilasyon ya anggad saray server rack. Say ambetel ya dagem et ipapaway ed tagey, kanian walay closed-loop cooling arrangement ya mamaaligwas ed enerhiya tan mamapaliis ed saray hotspot.
Saray Mainit ya Tag: micro cementitious raised access floor, China micro cementitious raised access floor manufacturers, suppliers, factory